EasyManuals Logo
Home>Cisco>Switch>AP775A - Nexus Converged Network Switch 5010

Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Cisco AP775A - Nexus Converged Network Switch 5010
886 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #788 background imageLoading...
Page #788 background image
Send document comments to nexus7k-feedback-doc@cisco.com
2-750
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
U6RIB Messages
Error Message U6RIB-2-TIMER_LIB Format: %s %s
Explanation The timer library returned an error, causing an unrecoverable problem for U6RIB.
Recommended Action Use 'reload' command to reload the system. Be aware that this problem affects
all VDCs on the system.
Error Message U6RIB-2-TOO_MANY_CLIENTS Format: %s client \%s\
Explanation U6RIB cannot add this client because the U6RIB client limit has already been reached.
Parameters: Resource, Client ...
Recommended Action Restart the component when the system is working.
U6RIB-3
Error Message U6RIB-3-AVLADD_ERROR Format: Could not add %s (0x%08x) to the %s avl
Explanation U6RIB was unable to add a piece of data to an AVL data structure.
Parameters: Data item, Memory address, Data structure ...
Recommended Action Use 'reload' command to reload the system. Be aware that this problem affects
all VDCs on the system.
Error Message U6RIB-3-AVLINIT_ERROR Format: Could not init %s avl for VRF %s
Explanation U6RIB was unable to correctly initialize an AVL data structure.
Parameters: AVL name, VRF-name ...
Recommended Action Use 'reload' command to reload the system. Be aware that this problem affects
all VDCs on the system.
Error Message U6RIB-3-ECMP_LDSHR Format: %s
Explanation Error related to ECMP load-share configuration which will affect load-sharing for
software-switched packets. If parity between hardware and software switching is important, perform
a switchover.
Recommended Action Requires operator to intervene.
Error Message U6RIB-3-GET_INSTANCE_ERROR Format: instance not found for client \%s\
in VRF %s
Explanation U6RIB could not find its data structures for a client in the shown VRF. The shown VRF
should be reconfigured in the client. i.e. in router sub-mode configuration, 'no vrf <vrf-name>'
Parameters: Client, VRF ...
Recommended Action Requires operator to intervene.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?