SVC Messages
Error Message SVC-2-SVC_SYSLOG_PATH_FAILURE: System health detected SVC packet path
failure for [chars].
Explanation The CSM has been brought down by the system health monitor. The system Health has
detected a failure in the packet path between the SVC interface on the CSM and the backplane. This
The system Health test is run periodically.
Recommended Action Issue a no shutdown on the SVC interface to bring the node back online. If a
subsequent packet path failure occurs, the CSM module should be replaced.
Error Message SVC-2-SVC_SYSLOG_URIFS_FAILURE: [chars] is unreachable for reason:
[chars]
Explanation SVC interface modflash is not accessible. Modflash is the name of the file system local
to the SVC interface, and is typically used for coredumps and temporary file transfers.
Recommended Action Please shutdown and bring up the SVC interface in question to regain access
to the modflash file system.
SVC-3
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_EC_ER_ACTIVATE_CLUSTER_IP_FAILED ) Activate cluster IP failed [chars]
Explanation The system is unable to activate the cluster IP for the config node. It will not be possible
to execute configuration commands.
Recommended Action 1. Shutting the interfaces of the node will force this node out of the cluster and
cause another node to become the config node, which should restore the ability to execute
configuration commands. 2. If the error persists, re-install the code on the node. The node will then
have to be removed and re-added back to the cluster. 3. Ensure that the software is at the latest level
on the cluster. If not, upgrade the cluster and if necessary repeat step 2 with the latest level of code.
4. If the error continues, ask IBM Product Support for assistance.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_EC_ER_BATT_FAILURE )
Battery Failed [chars]
Explanation The battery module on the Caching Services Module has failed. The nodes on the CSM
will have shutdown. Other log entries may accompany this error.
Recommended Action Reload the Caching Services Module. If the error persists, replace the Caching
Services Module.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals