2-653
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_COPY_COMPLETED )
Flash Copy Copied [chars]
Explanation The Flash Copy mapping or consistency group has entered the IDLE_COPIED state.
The target disk now contains a complete copy and is no longer dependent on the source.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_FC_ER_PREPARE_COMPLETED
) Flash Copy Prepared [chars]
Explanation The Flash Copy mapping or consistency group has entered the PREPARED state. It is
now possible to Start or Stop the mapping/group.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec]
SS_EID_IC_EV_CLUSTER_RECOVERY_COMPLETE ) Cluster recovery completed [chars]
Explanation Cluster recovery has completed successfully.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_IC_EV_IOGRP_ONE_OK ) One
node in the IO group is not available [chars]
Explanation Following node remove by the user, there is only one node left in the IO group.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec]
SS_EID_IC_EV_SECURE_DELETE_COMPLETE ) Virtual Disk format completed [chars]
Explanation The formatting (writing all zeros) to new extents of the Virtual Disk has completed.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SVC-6-NODE_INFO_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_COLDSTART ) Node
software started [chars]
Explanation The node software has been started (cold start).
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals