2-617
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SPAN Messages
Error Message SPAN-5-SPAN_CFG_REJECT_VSAN_SRC_PRESENT: Source VSAN [[dec]] removed
from session [[dec]].
Explanation Source VSANs are removed from the session as mixing of interface and VSANs is not
supported.
Recommended Action No action is required.
Error Message SPAN-5-SPAN_PSS_CORRUPTION: Span is starting stateless due to PSS
corruption
Explanation Due to unrecoverable PSS corruption error, SPAN starts stateless without any
configuration.
Recommended Action No action is required.
Error Message SPAN-5-STATELESS_RESTART: Span is restarting stateless.
Explanation Due to unrecoverable error, Span is starting stateless. The currently active sessions will
not be preserved. The user will have to reenter all of the configuration.
Recommended Action No action is required.
Error Message SPAN-5-STATELESS_RESTART_ON_ACTIVE: Span is restarting as Span on
active sup was restarted stateless.
Explanation Due to unrecoverable error, Span on active supervisor was restarted stateless. So, the
standby Span restarts to get in synchronizationwith the stateless Span on active.
Recommended Action No action is required.
SPAN-6
Error Message SPAN-6-SESSION_DOWN: Session [dec] is inactive ([chars])
Explanation Session [dec] is inactive now. Traffic for this session is no longer spanned.
Recommended Action Check the reason for session inactive using the command 'show span session'
and take corresponding action.
Error Message SPAN-6-SESSION_UP: Session [dec] is active, destination SD port
[chars]
Explanation Session [dec] is active now. You can monitor Spanned traffic at the destination SD port.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals