Send document comments to nexus7k-feedback-doc@cisco.com
2-168
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
ETHPORT Messages
Error Message ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error
disabled. Reason:[chars])
Explanation The system has detected that the interface has has detected an error during the
configuration.
Recommended Action Collect more information about the failed interface using the command 'show
port internal all interface [char]'. In most cases, you can recover using a 'shutdown' followed a 'no
shutdown' on the interface or remove and reinsert the fiber optic cable.
Error Message ETHPORT-2-IF_SEQ_ERROR: Error ([chars]) while communicating with
component [chars] for opcode [chars] ([chars])
Explanation A component has system error as a response to a port event sequence.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message ETHPORT-2-IF_SEQ_ERROR: Error ([hex]) while communicating with
component [chars] opcode:[chars] (for:[chars])
Explanation A component did not respond to a request in a stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message ETHPORT-2-SEQ_TIMEOUT: Component [chars] timed out on response to
opcode [chars] ([chars])
Explanation A component did not respond to a request in a stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message ETHPORT-2-SEQ_TIMEOUT: Component [chars] timed out on response to
opcode:[chars] (for:[chars])
Explanation A component did not respond to a request in a stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals