2-220
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FICON Messages
Error Message FICON-3-E_ASSIGN_PROHIBIT_PN_FAIL: [chars]
Explanation Logical port address cannot be prohibited.
Recommended Action Check port numbers in the command.
Error Message FICON-3-E_DUPLICATE_PN_ASSIGN_WARNING: [chars]
Explanation This port has the same port number assigned to other port in the same FICON VSAN.
No more than one port should have the same port number in each FICON VSAN.
Recommended Action Avoid duplicate number assignment in each FICON VSAN\n.
Error Message FICON-3-E_INVALID_PA_BRINGUP_FAIL: [chars]
Explanation This port either has an invalid port address assigned or has no port address assigned.
Recommended Action Assign a valid FICON port number to the port.
Error Message FICON-3-E_PORT_PROHIBIT_BRINGUP_FAIL: [chars]
Explanation This port has been prohibited. Prohibiting E or TE ports is not allowed. This port cannot
be configured in E mode or TE mode until the prohibit mask configuration is changed.
Recommended Action Correct the prohibit mask (PDCM) for this port if you wish to bring it up as
an E or TE port in a FICON VSAN\n.
Error Message FICON-3-E_UNASSIGN_NO_PN_FAIL: [chars]
Explanation Only port number already assigned can be removed.
Recommended Action Check port numbers in the command.
Error Message FICON-3-PDCM_CHANGE_REJ_E_PORT: [chars]
Explanation The FICON Prohibit Dynamic Connectivity Mask(PDCM) change rejected because an
E or TE port is being prohibited. Prohibiting an E or TE port in not allowed.
Recommended Action Correct the prohibit mask (PDCM) for this port if you wish to bring the port
up as an E or TE port in a FICON VSAN\n.
FICON-5
Error Message FICON-5-STARTING: FICON Manager process starting
Explanation FICON Manager process is being started.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals