2-404
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
MSDP Messages
Error Message MSDP-3-FM_ERROR Format: FM could not shut down MSDP process
Explanation MSDP could not process the disable-req from FM.
Recommended Action Dump core, and and and then restart component.
Error Message MSDP-3-INVALID_TLV Format: Invalid TLV, type: %d, length: %d from peer
%s
Explanation MSDP process received an invalid packet. Appropriate error packet returned.
Parameters: TLV type, TLV length, Peer IP address ...
Recommended Action No action is required.
Error Message MSDP-3-LIB_MTS_FAILED Format: %s failed in %s, errno: %s
Explanation Process failed to access the MSDP mts-queue.
Parameters: MTS function name, Function in which MTS function failed, Error message ...
Recommended Action No action is required.
Error Message MSDP-3-MALLOC_FAILED Format: %s failed in %s
Explanation MSDP process is out of free memory.
Parameters: Malloc function, Function in which Malloc failed ...
Recommended Action Configure the network or router to decrease the number of routes.
Error Message MSDP-3-MQ_FAILED Format: %s failed in %s, errno: %s
Explanation The MSDP process has failed to access the message-queue.
Parameters: MQ function name, Function in which MQ function failed, Error message ...
Recommended Action No action is required.
Error Message MSDP-3-MRIB_ROUTE Format: In %s, %s failed to add mrib route
Explanation The MSDP process has failed to add mRIB routes.
Parameters: Function name, mRIB_add_route ...
Recommended Action No action is required.
Error Message MSDP-3-MSDP_INIT Format: MSDP init failed: %s
Explanation MSDP process initialization has failed.
Parameters: Component Name ...
Recommended Action Dump core, and then restart component.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals