EasyManuals Logo

Cisco AP775A - Nexus Converged Network Switch 5010 Reference

Cisco AP775A - Nexus Converged Network Switch 5010
886 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #708 background imageLoading...
Page #708 background image
Send document comments to nexus7k-feedback-doc@cisco.com
2-670
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC_BATTERY-SLOT# Messages
Error Message SVC_BATTERY-SLOT#-2-COMMUNICATION_FAILURE: Communication failure
with battery [dec].
Explanation The module encountered failures while communicating with a battery.
Recommended Action Replace the battery.
Error Message SVC_BATTERY-SLOT#-2-CONDITIONING_DISABLED: Temperature outside
permitted range for battery conditioning (5C-40C).
Explanation The temperature of the line card is not within the range to permit battery conditioning.
Recommended Action Make sure the temperature of the line card is between 5C and 40C.
Error Message SVC_BATTERY-SLOT#-2-DISCHARGING_FAILURE: Discharging failure in
battery [dec] ([hex]).
Explanation The module encountered failures while discharging a battery.
Recommended Action Replace the battery.
SVC_BATTERY-SLOT#-4
Error Message SVC_BATTERY-SLOT#-4-BATTERY_CAPACITY_LOW: Battery capacity is below
the required threshold.
Explanation The battery is lower than the required threshold.
Recommended Action Make sure the temperature is within the range to allow charging.
SVC_BATTERY-SLOT#-6
Error Message SVC_BATTERY-SLOT#-6-BATTERY_CAPACITY_OK: Battery capacity is above
the required threshold.
Explanation The battery is above the required threshold.
Recommended Action No action is required.
Error Message SVC_BATTERY-SLOT#-6-CONDITIONING_CANCELLED: Temperature outside
permitted range for battery conditioning (5C-40C). Battery [dec] conditioning
cancelled.
Explanation The temperature of the line card is not within the range to permit battery conditioning.
Recommended Action Make sure the temperature of the line card is between 5C and 40C.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals