Error Message MRIB-3-CV_INIT Format: Couldn't init cond var %s
Explanation The MRIB process has failed to initialize a conditional-variable resource.
Parameters: Thread Name ...
Recommended Action Dump core, and then restart component.
Error Message MRIB-3-FTM_BAD_METER Format: %s failed for meter %s in %s
Explanation The MRIB process has failed to configure the multicast meter.
Parameters: FTM Operation, Type, Function ...
Recommended Action No action is required.
Error Message MRIB-3-FTM_BAD_MINOR Format: Unknown FTM mtype: 0x%4x
Explanation MRIB process received unsupported message type from FTM, igored.
Parameters: Minor Type ...
Recommended Action No action is required.
Error Message MRIB-3-FTM_NO_XID Format: Cannot find FTM buffer, xid: %d
Explanation MRIB process could not match the sequence number for FTM message, igored.
Parameters: Trasaction ID ...
Recommended Action No action is required.
Error Message MRIB-3-INHERIT_FAILED Format: mrib_inherit_oifs(): bitfield is set
but oif doesn't exist
Explanation The MRIB process has failed in inheriting OIFs for the (S,G) from (*,G).
Recommended Action No action is required.
Error Message MRIB-3-INIT_SDB Format: %s Return Code: 0x%x Error String: %s
Explanation SDB initialization has failed
Parameters: Message Return Code Error String ...
Recommended Action No action is required.
Error Message MRIB-3-KSINK_LIB_ERROR Format: %s %s
Explanation A error was encountered during ksink operations.
Parameters: Error Description, MRIB Function ...
Recommended Action No action is required.