FLOGI Messages
Error Message FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: [VSAN [dec], Interface [chars]]
FLOGI rejected - FCID allocation failed.
Explanation An FLOGI was rejected because the FCID allocation failed.
Recommended Action Check the fcid-interop configuration, purge the persistency table and check the
output of show flogi database details and see if any of the A area FCID allocation entries can be
configured to single fcid allocation as per Configuration Guide.
Error Message FLOGI-1-MSG_FLOGI_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface
[chars]] FLOGI rejected - this interface has reached the max num of NL-Ports
([dec])
Explanation An FLOGI was rejected because the FL-Port has reached the maximum allowed number
of devices.
Recommended Action Reduce the number of devices on the loop.
Error Message FLOGI-1-MSG_NPIV_NOT_SUPPORTED_WITH_TRUNKING: [VSAN [dec], Interface
[chars]] NPIV not supported - on this platform, NPIV is not supported on trunking
interfaces
Explanation The N_Port requested NPIV, but this platform does not support NPIV on trunking
F_Ports.
Recommended Action Disable NPIV, or move the N_Port to a switch that supports NPIV on trunking
F_Ports.
FLOGI-2
Error Message FLOGI-2-MSG_FLOGI_REJECT_NO_ACL_TCAM_AVAILABLE: [VSAN [dec],
Interface [chars]] FLOGI rejected - ACLTCAM resource exausted
Explanation An FLOGI was rejected because the ACLTCAM hardware resource is completely used.
Recommended Action Reduce the number of nodes.
FLOGI-4
Error Message FLOGI-4-MSG_VF_FLOGI_FROM_NON_CISCO_OUI: [VSAN [dec], Interface
[chars]] FLOGI with VF bit set from OUI [hex]:[hex]:[hex] (nwwn: [chars])
Explanation This interface received an FLOGI with VF bit set from a nonCisco OUI; in this release
Virtual Fabrics are not supported on interfaces connected to third-party devices.
Recommended Action Set the trunk mode of this interface to off.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals