2-227
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FSPF Messages
Error Message FSPF-3-UNLOCK_FAIL: FSPF failure in releasing lock
Explanation There is a software failure in releasing lock of the shared resource between FSPF
threads.
Recommended Action Provide output of 'debug fspf all '.
Error Message FSPF-3-VSAN_TIMER_ERR: Error in processing VSAN timer event [chars],
error description = [chars]
Explanation FSPF had an internal error in processing timer event , error description is [chars].
Recommended Action Provide output of 'debug fspf error'.
FSPF-4
Error Message FSPF-4-FC2_DOWN_INTF: Received FC2 packet on DOWN interface [chars]
Explanation FSPF received a FC2 packet on inactive interface [chars] .
Recommended Action This message may be printed for the first FSPF packet when an interface is
brought up. If the message is seen continuously check if FSPF is disabled on one end for the
interface or the VSAN. Otherwise check 'show interface ' output to see if interface is physically up
only on one side. Also check if there is any error message printed for IPC_PROC_ERR.
Error Message FSPF-4-FC2_DOWN_VSAN: Received FC2 packet on inactive vsan
Explanation FSPF received a FC2 packet on inactive VSAN.
Recommended Action If message seen continuously check if FSPF is disabled on the VSAN
Investigate if VSAN is active and valid domain has been assigned on the switch Also check if
IPC_PROC_ERR message is printed in the syslog.
Error Message FSPF-4-ILLEGAL_FSM_EVENT: Illegal FSM event for state [chars] in
interface [chars]
Explanation An illegal protocol event has occurred for the FSPF state machine. The old state was
[chars] for the interface [chars].
Recommended Action It is possible to get this message if some protocol packet gets dropped but the
system should recover and move back to FULL state. Do 'show fspf interface' to check the state of
the interface. If it is stuck in state other than FULL provide output of 'debug fspf event' and 'debug
fspf fc pkt ' for the interfaces involved.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals