Error Message DIAGCLIENT-2-DIAG_BOOTUP_COMPLETE: Module <[dec]> Bootup Test
<[chars]> has reported <[chars]>
Explanation Bootup Test completed.
Recommended Action Nothing to be done if the test reports SUCCESS otherwise copy the error
message exactly as it appears on the console, gather the output of show tech-support, and contact
your Cisco technical support representative with the gathered information.
Error Message DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <[chars]> has been disabled
as a part of default EEM action
Explanation Informational Syslog.
Recommended Action No action is required.
Error Message DIAGCLIENT-2-PSS_READ_FAILURE: Read from PSS failed on Module <[dec]>
Explanation Read operation from PSS store failed.
Recommended Action No action is required.
Error Message DIAGCLIENT-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]>
Explanation Write operation on PSS store failed.
Recommended Action No action is required.
DIAGCLIENT-3
Error Message DIAGCLIENT-3-DIAG_HM_FAIL: Module <[dec]> Health Monitoring Test
<[chars]> has failed. Please use 'show diagnostic result <target>' to see test
results
Explanation A Health Monitoring Test has reported failure.
Recommended Action Ensure the line card is firmly in the slot, reseat if necessary, and attempt to run
the test again if the line card is not seated properly in the slot. If the line card was properly seated
in the slot, copy the error message exactly as it appears on the console, gather the output of show
tech-support, and contact your Cisco technical support representative with the gathered information.