2-172
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
ETHPORT Messages
Error Message ETHPORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED: Interface [chars] is down
(Isolation due to domain manager disabled)
Explanation Isolated due to domain manager being disabled.
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE: Interface
[chars] is down (Isolation due to domain manager other side not responding)
Explanation Remote end domain manager not responding.
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED: Interface
[chars] is down (Isolation due to domain other side eport isolated)
Explanation Isolating this interface due to the remote end being isolated.
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION: Interface [chars] is down
(Isolation due to domain overlap)
Explanation Isolated due to domain overlap.
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_ELP_FAILURE_ISOLATION: Interface [chars] is down
(Isolation due to ELP failure)
Explanation ELP failed on the interface.
Recommended Action Check the output of 'show port internal info' in the 'ELP failure reason' field.
Error Message ETHPORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error
Disabled - EPP Failure)
Explanation Trunk protocol failed.
Recommended Action 'show port internal event-history msgs' will indicate the trunk protocol
exchanges to determine why it failed.
Error Message ETHPORT-5-IF_DOWN_ESC_FAILURE_ISOLATION: Interface [chars] is down
(Isolation due to ESC failure)
Explanation ESC failed on the interface.
Recommended Action Check the output of 'show port internal event-history' to determine the ESC
protocol exchanges to determine how it failed.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals