Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
FCDOMAIN Messages
Error Message FCDOMAIN-6-FCIDNOTSTORED: FCIDs not stored
Explanation FCIDs not stored.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCIDP_ENABLED_DOM_TYPE_PREFERRED: FCID persistency is
enabled, but the domain ID type is configured as preferred
Explanation The FCID persistency feature is enabled, but the domain ID type is configured as
preferrored. This means that with a low probability the domain ID of the local VSAN might change
afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a
principal link flaps. A principal link is either an upstream or a downstream link. Should the domain
ID change, all the FCIDs associated with it would be invalidated.
Recommended Action Type [fcdomain domain <dom-id> static VSAN <VSAN-id>] to configure as
static the domain ID type in an existing VSAN.
Error Message FCDOMAIN-6-FCIDS_ASSIGNED: Assigned a sequence of 256 contiguous
FCIDs starting from FCID [hex]:[hex]:[hex]
Explanation Assigned a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCIDS_FREED: Freed a sequence of 256 contiguous FCIDs
starting from FCID [hex]:[hex]:[hex]
Explanation Freed a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-INCORRECTDOMAIN: Requested FCIDs with domain field
different from local domain
Explanation Requested FCIDs with domain field different from local domain.
Recommended Action No action is required.
Error Message FCDOMAIN-6-INCORRECTDOMAINRANGE: Requested FCIDs with domain field
not in expected range
Explanation Requested FCIDs with domain field not in expected range.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals