Error Message IP-3-IP_THR_CREATE Format: Failed to create %s thread. error %d
Explanation A failure occurred while creating a thread.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message IP-3-IP_TLV_TO_STRUCT Format: TLV to Struct Conversion failed (%d)
Explanation TLV to Struct conversion failed.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message IP-3-IP_UNK_MSG Format: Unrecognized message major type %d, minor type
%d
Explanation An unknown message was received from another process.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message IP-3-MRIB_ADD_ROUTE Format: MRIB add route failed in %s for VRF %s
Explanation An IP process has failed to add route in MRIB.
Parameters: Function Name, Context Name ...
Recommended Action No action is required.
Error Message IP-3-MRIB_DELETE_ROUTE Format: MRIB delete route failed in %s for VRF
%s
Explanation An IP process has failed to delete route from MRIB.
Parameters: Function Name, Context Name ...
Recommended Action No action is required.
Error Message IP-3-MV_INIT Format: Couldn't init mutex %s
Explanation An IP process has failed to initialize the mutex system resource.
Parameters: Thread Name ...
Recommended Action Dump core, and then restart component.
Error Message IP-3-NO_SH_MEM Format: Failed to allocate shared memory %s
Explanation The IP process has run out of shared memory.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals