IPFC Messages
IPFC-2
Error Message IPFC-2-ALLOC_MEMORY: Memory allocation failed
Explanation The service failed to allocate a block of dynamic memory.
Recommended Action No action is required.
IPFC-3
Error Message IPFC-3-INIT_FAILED: Initialization failed. Component [chars]
Explanation The system has detected that the service has failed to start. The failure occurred while
initializing the component [chars].
Recommended Action Enter the show processes command to check the status of the other processes,
debug the specified component.
Error Message IPFC-3-IOCTL_FAILED: IOCTL failed
Explanation An IOCTL to the character device failed.
Recommended Action Show IPFC internal interface VSAN <number> for all the configured VSAN
interfaces to check the internal status, show IPFC internal MIP to check the internal status.
Error Message IPFC-3-PSSERROR: [chars]
Explanation IPFC manager encountered a PSS error.
Recommended Action No action is required.
IPFC-5
Error Message IPFC-5-CONFIG_EVENT: VSAN interface [dec] [chars]
Explanation The specified VSAN The system has detected that the interface has been successfully
[chars].
Recommended Action No action is required.
Error Message IPFC-5-STATE_CHANGE: VSAN interface [dec] [chars]
Explanation The specified VSAN interface is [chars].
Recommended Action No action is required.