Page #369 background imageLoading...
Page #369 background image
Send document comments to nexus7k-feedback-doc@cisco.com
2-331
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
IVR Messages
Error Message IVR-2-PERSISTENT_VIRTUAL_FCID_CONFLICT_WITH_AUTOLEARN: Persistent
virtual fcid and dynamic pfcid entries
Explanation This can happen if conflict happens during persistent virtual domain, or virtual fcid
entry configuration.
Recommended Action Please assign a non-conflict persistent virtual domain or fcid entry with
current dynamic entries.
Error Message IVR-2-PERSISTENT_VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the
configured persistent virtual domain/fcid could not be assigned
Explanation This can happen if the virtual domain/fcid configured by the user is - a) Already in use
(either by IVR or a real switch) b) Not allowed due to interop mode or allowed domain list.
Recommended Action Please make sure that the configured virtual domain/fcid is allowed and
available for use.
Error Message IVR-2-VIRTUAL_DOMAIN_CONFLICT: In VSAN [dec] virtual domain [dec]
from native VSAN [dec] conflicts with native VSAN [dec] for the same virtual domain
Explanation Currently advertised virtual domain [dec] in VSAN [dec] is native to VSAN [dec]. This
switch has learned of a device that is member of active IVR zone and has the same domain ID, but
belongs to a different native VSAN. This device would not be advertised in that VSAN until the
domain conflict is resolved.
Recommended Action No action is required.
Error Message IVR-2-VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the internally
generated FCID conflicts with fcid assigned to WWN [chars]. Please configure fcid
for WWN [chars] too
Explanation This can happen if the virtual domain/fcid internally configured is already in use by
another active device.
Recommended Action Please assign a different persistent virtual fcid by command.
IVR-3
Error Message IVR-3-AAM_MODE_CANNOT_CHANGE: AAM mode cannot be changed. Might cause
the fabric NAT mode inconsistency
Explanation The IVR NAT is not enabled.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals