2-476
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
PLATFORM Messages
PLATFORM-1
Error Message PLATFORM-1-FABRIC_SWITCH_FAN_FAIL: Less than 4 required fans
operating.
Explanation Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced.
This can lead to overheating and temperature alarms.
Recommended Action Enter the 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-1-FAN_FAIL: Fan module Failed
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and
temperature alarms.
Recommended Action Enter the 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-1-MDS9124_FAN_FAIL: Less than 4 required fans operating.
Explanation Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced.
This can lead to overheating and temperature alarms.
Recommended Action Enter the 'the show platform internal command
rmationcommandrmationcommand' to collect more information.
Error Message PLATFORM-1-PFM_ALERT: [chars]
Explanation Platform Alert.
Recommended Action No action is required.
Error Message PLATFORM-1-PS_SINGLE_INPUT: Both power inputs are connected for Power
supplies, remove single-input configuration for optimal power usage
Explanation Current power supply redundancy mode may not be optimal.
Recommended Action Enter a 'show environment power' and 'the show platform internal command
rmationcommand' to collect more information.
Error Message PLATFORM-1-XBAR_PWRDENY: Xbar [dec] can not be powered up due to
insufficient power (Serial number [chars])
Explanation Available power in power supplies is not sufficient to power up the xbar.
Recommended Action You can verify available power and current usage using the command 'show
env power'. Refer to power supply document on how to increase power supply capacity.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals