Send document comments to nexus7k-feedback-doc@cisco.com
2-633
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SVC Messages
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_FAIL )
Logical Fibre Channel port reported failed [chars]
Explanation No active/functioning logical FC port was detected by the software.
Recommended Action Reload the node. If the problem persists, replace the Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_ADAP_QUANTITY )
Logical Fibre Channel port missing [chars]
Explanation No active/functioning FC port was detected by the software.
Recommended Action Reload the node. If the problem persists, replace the Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_FC_PORT_QUANTITY )
Logical Fibre Channel port reported not operational [chars]
Explanation No active/functioning logical FC port was detected by the software.
Recommended Action Reload the node. If the problem persists, replace the Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_NODE_WARMSTART )
Node warmstarted due to software error [chars]
Explanation The error that is logged in the cluster error log indicates a software problem in the
cluster.
Recommended Action 1. Ensure that the software is at the latest level on the cluster. 2. Run a
configuration dump and a logged data dump. Save the dump data. 3. Contact the Cisco Technical
Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac. 4. Mark the
error you have just repaired as fixed.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec] SS_EID_PL_ER_POWER_DOMAIN )
Power domain error [chars]
Explanation The two nodes in an IO group are on the same Caching Services Module.
Recommended Action Determine what the configuration should be. Remove one of the nodes and add
a node to the IO group which is not on the same Caching Services Module.
Error Message SVC-3-NODE_ERR_MSG: (SVC [dec]/[dec]
SS_EID_VG_ER_MDISK_GROUP_OFFLINE ) A Managed Disk group is offline [chars]
Explanation An Mdisk group is offline.
Recommended Action 1. Repair the enclosure or disk controller. 2. Start a cluster discovery
operation. 3. Check managed disk status. If all managed disks show a status of online, mark the error
you have just repaired as fixed.