2-693
Cisco NX-OS System Messages Reference
OL-15994-03
Chapter 2 System Messages and Recovery Procedures
SYSMGR Messages
Error Message SYSMGR-2-SRV_MINOR_MEMORY_ALERT: service [chars] minor memory alert
([dec]%)
Explanation Minor Memory Alert Event received.
Recommended Action No action is required.
Error Message SYSMGR-2-SRV_SPAWN_FAILED: Spawning of service [chars] in vdc [dec]
failed : [chars] (error-id [hex]).
Explanation Failed to spawn a service.
Recommended Action No action is required.
Error Message SYSMGR-2-STANDBY_BOOT_FAILED: Standby supervisor failed to boot up.
Explanation This message is printed if the standby supervisor does not complete its boot procedure
(i.e. it does not reach the login prompt on the local console) 3 to 6 minutes after the loader has been
loaded by the BIOS. This message is usually caused by boot variables not properly set for the
standby supervisor. This message can also be caused by a user intentionally interrorupting the boot
procedure at the loader prompt (by means of pressing ESC).
Recommended Action Connect to the local console of the standby supervisor. If the supervisor is at
the loader prompt, try to use the 'boot' command to continue the boot procedure. Otherwise, issue a
'reload' command for the standby supervisor from a vsh session on the active supervisor, specifying
the 'force-dnld' option. Once the standby is online, fix the problem by setting the boot variables
appropriately.
Error Message SYSMGR-2-START_SCRIPT_FAILED: Start script (/isan/etc/rc.sysmgr
start) failed with return value: ([dec]).
Explanation The initialization of the system could not complete.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco
Support web site http://www.cisco.com/tac.
Error Message SYSMGR-2-STARTUP_CONVERSION_FAILED: Startup config conversion failed
during boot (error-id [hex]).
Explanation This message indicates that the conversion of startup configuration failed during boot.
Recommended Action If the problem persists, please use the vshboot command 'init system' to
initialize the configuration partition.
Error Message SYSMGR-2-SUBPROC_SPAWN_FAILED: Spawning of sub-process [chars] in vdc
[dec] failed : [chars] (error-id [hex]).
Explanation Failed to spawn a sub-process.
Recommended Action No action is required.

Table of Contents

Other manuals for Cisco AP775A - Nexus Converged Network Switch 5010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco AP775A - Nexus Converged Network Switch 5010 and is the answer not in the manual?

Cisco AP775A - Nexus Converged Network Switch 5010 Specifications

General IconGeneral
BrandCisco
ModelAP775A - Nexus Converged Network Switch 5010
CategorySwitch
LanguageEnglish

Related product manuals