SYSTEMHEALTH Messages
Error Message SYSTEMHEALTH-2-OHMS_TCAM_PARITY_OFLOW: Too many TCAM Parity errors
detected on module [dec]
Explanation More parity errors than that can be corrected were detected on the affected module.
Recommended Action Please schedule a downtime and reload the module. If these errors continue to
happen even after module reload, please replace the module.
SYSTEMHEALTH-4
Error Message SYSTEMHEALTH-4-OHMS_BATTERY_ERRORS: Battery test on module [dec] has
been suspended due to internal errors.
Explanation Battery test internal errors.
Recommended Action No action is required.
Error Message SYSTEMHEALTH-4-OHMS_BOOTFLASH_TEST_ERRORS: Bootflash test cannot
proceed due to internal errors on module [dec].
Explanation Compact flash test internal errors.
Recommended Action No action is required.
Error Message SYSTEMHEALTH-4-OHMS_CACHE_DISK_ERRORS: Cache disk test on module
[dec] dpp [dec] has been suspended due to internal errors.
Explanation Cache disk test internal errors.
Recommended Action No action is required.
Error Message SYSTEMHEALTH-4-OHMS_CF_CRC_PASSED: Compact Flash firmware on module
[dec] is healthy at this time.
Explanation The Compact Flash model has data retention issues and needs to be replaced.
Recommended Action Please schedule a downtime and replace the compact flash on this module.
Error Message SYSTEMHEALTH-4-OHMS_CF_REFLASH_PASSED: Compact Flash firmware was
successfully refreshed on module [dec].
Explanation The Compact Flash model has data retention issues and needs to be replaced.
Recommended Action Please schedule a downtime and replace the compact flash on this module.