iControl Messages
6-33
6
iControl DC
Emergency Power Recall, EMERG POWER RECALL. See Emergency Power Activated.
Description: This event is logged when the elevator has been commanded to lower to the emergency power
recall floor.
Car Reaction: The elevator proceeds to the user-defined emergency power recall floor. Door operation at the
recall floor is in accordance with the user defined door operation under emergency power recall conditions.
Troubleshooting:
1. Related inputs:
EPR: Normally low (high to lower the car)
PTR: Normally low (low to lower the car)
Emergency Power Recall (In Service), EP RECALL-IN SERVICE
Description: This event is logged and related car status messages displayed on the OBD and iView if a car
that has been commanded to recall during emergency power remains in service for car calls.
Car Reaction: An attendant operated car (FIRE II, IND, ATS, CFSS In-Car, EMS) goes back into service for car
calls only when it is selected to recall. The car is shut down once it is at a floor with doors open or if the car
fails to move or open its doors within a user defined timer (30 seconds).
Troubleshooting: Check the Emergency Power Version option (System > Configuration > Emergency Power)
and set it to Pre 2008 if this operation is not desired.
Emergency Power Run, EMERG POWER RUN. See Emergency Power Activated.
Description: This elevator is allowed to respond to calls during emergency power operation.
Troubleshooting:
1. Related inputs (only on elevators with emergency power overlay operation)
EPR: Normally low (low to run the car)
PTR: Normally low (low to run the car)
Emergency Power Shutdown, EMERG POWER SHUTDOWN. See Emergency Power Activated.
Description: This event is logged when emergency power is initially activated or if communication with the
emergency power supervisor has been lost while on emergency power.
Car Reaction: Emergency stop. Car removed from service.
Troubleshooting:
1. Related inputs:
EPI: Active level field adjustable.
Emergency Stop Input Activated, EMERGENCY STOP INPUT
Description: The events are logged and related car status messages displayed on the OBD and iView to
reflect the status of the Emergency Stop Input.
Car Reaction: When the Emergency Stop Input is activated, the car makes an emergency stop and cancels
all calls. This input has priority over all modes of operation including Fire Service.
Troubleshooting: Check the status of the Emergency Stop Input.
Emergency Stop Input Deactivated see Emergency Stop Input Activated.
ETA Mode Activated
Description: The Estimated Time of Arrival dispatching engine is now active.
Event Log Cleared
Description: Indicates that all of the events previously logged in the event log were removed using the “Clear
all” button (iView Controller > View > Diagnostics > Event Log tab).