Configuration - I/O Boards
9-141
9
iControl DC
• In-Car Fire Door Operation: This output is typically used by the freight door controller
to adjust the door operation per the code requirements for in-car fire service and in-
car fire service recall operations. This output is ON during in-car fire service and also
during in-car fire service recall until the doors are fully closed.
• In-Car Fire Hold: This output is ON during In-car fire service hold operation.
• In-Car Fire Recall: Typically used to re-enable the hall door buttons station during in-
car fire service recall, this output is ON during In-car fire service recall operation.
• In-Car Inspection: Active when the car is on in-car inspection operation.
• In Use Light: This output turns on when the car doors are not fully closed or there is a
demand to move the car.
• In Use Light 2: Used in conjunction with Single Automatic Push button option. This
output is ON when there is a registered call (hall or car call) and remains ON until all
door dwell times have expired. The output is OFF when the car is idle with doors open.
• Independent Service Indicator: Active when the car is on Independent service.
• Inspection Output: Active when the car is on any Inspection operation.
• Light Load: Activated when the Light Load Input is active or when the weight in the
car, detected by an analog load weigher, is less than the Light load threshold.
• Machine Room Inspection: Active when the car is on machine room inspection opera-
tion.
• Mechanically In Service: This output is “normally” active (when the car is running nor-
mally), but is turned off when the car appears to be mechanically out of service. Only
two statuses are checked for clearing this output: Safety String and Motor Limit Timer.
• Overload: This output is on when the overload threshold, value at which it may be con-
sidered unsafe to move the elevator, has been reached. The car will remain at the floor
with doors open (overridden by fire phase II). Typically a visual and/or audible indica-
tor is used to alert passengers that the car is overloaded.
• Pass Code Failure: Activated momentarily when the time limit expires prior to a cor-
rect pass code having been entered on the Car Operating Panel.
• Pass Code Success: Activated momentarily when a correct pass code is entered at the
Car Operating Panel.
• Passing Floor Gong: This output is on whenever the car passes a floor. Timer options
are located on the iView Configuration > Car Operation > Devices tab.
• Passing Floor Gong Enabled: This output comes on whenever the car passes a floor
and the passing floor gong enable button has been pushed. Timer options are located
on the iView Configuration > Car Operation > Devices tab.
• Recall Command: This output comes on when the car has been placed in Recall mode
via software command (iMonitor) recalling it to a desired floor. The recall floor, door
operation, car call disposition, action at the destination floor, etc., are user settings
which are sent with the command.
• Recall Complete Command: This output turns on when a recall initiated via software
command (iMonitor) has been completed.
• Recall Complete Switch 1 through 6: The output, corresponding to the Recall switch
that initiated the recall, turns on when the recall has been completed.
• Recall Switch 1 through 6: One of six outputs indicating that its respective switch has
been activated and has placed a car in Recall mode, recalling it to an assigned floor.