Configuration - I/O Boards
9-141
9
iControl DC
In-Car Fire Door Operation: This output is typically used by the freight door controller
to adjust the door operation per the code requirements for in-car fire service and in-
car fire service recall operations. This output is ON during in-car fire service and also
during in-car fire service recall until the doors are fully closed.
In-Car Fire Hold: This output is ON during In-car fire service hold operation.
In-Car Fire Recall: Typically used to re-enable the hall door buttons station during in-
car fire service recall, this output is ON during In-car fire service recall operation.
In-Car Inspection: Active when the car is on in-car inspection operation.
In Use Light: This output turns on when the car doors are not fully closed or there is a
demand to move the car.
In Use Light 2: Used in conjunction with Single Automatic Push button option. This
output is ON when there is a registered call (hall or car call) and remains ON until all
door dwell times have expired. The output is OFF when the car is idle with doors open.
Independent Service Indicator: Active when the car is on Independent service.
Inspection Output: Active when the car is on any Inspection operation.
Light Load: Activated when the Light Load Input is active or when the weight in the
car, detected by an analog load weigher, is less than the Light load threshold.
Machine Room Inspection: Active when the car is on machine room inspection opera-
tion.
Mechanically In Service: This output is “normally” active (when the car is running nor-
mally), but is turned off when the car appears to be mechanically out of service. Only
two statuses are checked for clearing this output: Safety String and Motor Limit Timer.
Overload: This output is on when the overload threshold, value at which it may be con-
sidered unsafe to move the elevator, has been reached. The car will remain at the floor
with doors open (overridden by fire phase II). Typically a visual and/or audible indica-
tor is used to alert passengers that the car is overloaded.
Pass Code Failure: Activated momentarily when the time limit expires prior to a cor-
rect pass code having been entered on the Car Operating Panel.
Pass Code Success: Activated momentarily when a correct pass code is entered at the
Car Operating Panel.
Passing Floor Gong: This output is on whenever the car passes a floor. Timer options
are located on the iView Configuration > Car Operation > Devices tab.
Passing Floor Gong Enabled: This output comes on whenever the car passes a floor
and the passing floor gong enable button has been pushed. Timer options are located
on the iView Configuration > Car Operation > Devices tab.
Recall Command: This output comes on when the car has been placed in Recall mode
via software command (iMonitor) recalling it to a desired floor. The recall floor, door
operation, car call disposition, action at the destination floor, etc., are user settings
which are sent with the command.
Recall Complete Command: This output turns on when a recall initiated via software
command (iMonitor) has been completed.
Recall Complete Switch 1 through 6: The output, corresponding to the Recall switch
that initiated the recall, turns on when the recall has been completed.
Recall Switch 1 through 6: One of six outputs indicating that its respective switch has
been activated and has placed a car in Recall mode, recalling it to an assigned floor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MCE iControl and is the answer not in the manual?

MCE iControl Specifications

General IconGeneral
BrandMCE
ModeliControl
CategoryController
LanguageEnglish