Configuration - I/O Boards
9-145
9
iControl DC
• Hall lanterns - Rear down
• Hall lantern - Rear down, Floor 1—96:This output is generated to activate the rear door
hall gong/lantern assembly. Options are set on the Configuration > Car Operation >
Devices tab.
•Hall gongs - Front
• Hall gongs - Front, Floor 1—96: This output is generated to activate a separate front
door hall gong.
•Hall gongs - Rear
• Hall gongs - Rear, Floor 1—96: This output is generated to activate a separate rear door
hall gong.
• Motor and Drive
• Brake Holding Voltage: This output turns ON for hardware driven Brake picking to
Holding voltage. The Hold delay timer option is located on Configuration > Brake >
Timers tab.
• Motor Blower: This output for the Motor Blower is ON when car is in motion and for
the duration of the time setting of the Motor blower hold delay timer on the Configura-
tion > Drive > General tab.
• Sheave Brake Enable: Used to enable the emergency brake function. The Emergency
Brake - Sheave brake options must be selected on the Configuration > Safety tab.
• Melina PI display Outputs I (Left)
• Left Character 9—22: Outputs to the Melina position indicator for the left character.
Outputs I will stay active during Fire Service.
• Melina PI display Outputs I (Middle)
• Middle Character 9—22: Outputs to the Melina position indicator for the middle char-
acter. Outputs I will stay active during Fire Service.
• Melina PI display Outputs I (Right)
• Right Character 9—22: Outputs to the Melina position indicator for the right charac-
ter. Outputs I will stay active during Fire Service.
• Melina PI display Outputs II (Left)
• Left Character 9—22: Outputs to the Melina position indicator for the left character.
Outputs II will deactivate during Fire Service.
• Melina PI display Outputs II (Middle)
• Middle Character 9—22: Outputs to the Melina position indicator for the middle char-
acter. Outputs II will deactivate during Fire Service.
• Melina PI display Outputs II (Right)
• Right Character 9—22: Outputs to the Melina position indicator for the right charac-
ter. Outputs II will deactivate during Fire Service.
• System Configurations (Simplex)
• Hall Call Eligibility Config (1 - 8): Output is active when the respective Hall Call Eligi-
bility Configuration (1 - 8) is active.
• Parking Config (1 - 8): Output is active when the respective Parking Configuration (1 -
8) is active.
• Parking Eligibility Config (1 - 8): Output is active when the respective Parking Eligibil-
ity Configuration (1 - 8) is active.