iView - System View
10-66 Manual # 42-02-7223
Hall call enable 1 (2) - Up main rear input: When active, a valid call at the associated
secured floor, up main rear riser, can be registered. Select floor number in Association
column.
NOTE: The inputs above are OR’ed together with the greater permission exerting control.
CFSS call enable 1 (or 2) inputs
CFSS call enable 1 (2) - CFSS mode 1 input: When active, a valid CFSS mode 1 call at
the associated secured floor, can be registered. Select the floor number in the Associa-
tion column. (CFSS mode 1 and 2 are user-assignable operating modes typically used
for medical emergency calls, attendant calls, etc.)
CFSS call enable 1 (2) - CFSS mode 1 front input: When active, a valid CFSS mode 1 call
at the associated secured floor, front opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
CFSS call enable 1 (2) - CFSS mode 1 rear input: When active, a valid CFSS mode 1 call
at the associated secured floor, rear opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
CFSS call enable 1 (2) - CFSS mode 2 input: When active, a valid CFSS mode 2 call at
the associated secured floor, can be registered. Select the floor number in the Associa-
tion column. (CFSS mode 1 and 2 are user-assignable operating modes typically used
for medical emergency calls, attendant calls, etc.)
CFSS call enable 1 (2) - CFSS mode 2 front input: When active, a valid CFSS mode 2
call at the associated secured floor, front opening only, can be registered. Select the
floor number in the Association column. (CFSS mode 1 and 2 are user-assignable oper-
ating modes typically used for medical emergency calls, attendant calls, etc.)
CFSS call enable 1 (2) - CFSS mode 2 rear input: When active, a valid CFSS mode 2 call
at the associated secured floor, rear opening only, can be registered. Select the floor
number in the Association column. (CFSS mode 1 and 2 are user-assignable operating
modes typically used for medical emergency calls, attendant calls, etc.)
Security Override
Security override - Master security override input: When active, all secured calls are
enabled. All secured car and hall calls will behave as though unsecured. Locked calls
will remain locked.
Security override - Hall call enable 1 override input: When active, all Enable 1 secured
hall calls are unsecured. Locked calls will remain locked.
Security override - Hall call enable 2 override input: When active, all Enable 2 secured
hall calls are unsecured. Locked calls will remain locked.
Split bank hall calls: When enabled and active, split bank operation allows a single control
group of cars to be controlled as though it were two separate groups. These inputs provide
connection points for the auxiliary and main riser hall call buttons for the cars split from
the group (Bank B).
Bank B hall call - Down aux front
Bank B hall call - Down aux rear
Bank B hall call - Up aux front
Bank B hall call - Up aux rear