Configuration Tabs - System I/O
10-65
10
iControl DC
Security: The following inputs control how hall calls to secured floors are handled by the sys-
tem. They are typically activated from switches or buttons at the building security station so
that security personnel can easily and quickly make adjustments to hall call security as a situa-
tion demands. They can also be activated by a card reader or keypad, etc.
• Hall call enable 1 (or 2) inputs
• Hall call enable 1 (2) - Floor input: When active, a valid call for the secured floor can be
registered. Select floor number in Association column.
• Hall call enable 1 (2) - Front input: When active, a valid call for the front opening on
the associated secured floor can be registered. Select floor number in Association col-
umn.
• Hall call enable 1 (2) - Rear input: When active, a valid call for the rear opening on the
associated floor can be registered. Select floor number in Association column.
• Hall call enable 1 (2) - Main front input: When active, valid secured calls at the associ-
ated floor, main front riser, can be registered. Select floor number in Association col-
umn.
• Hall call enable 1 (2) - Main rear input: When active, a valid call at the associated
secured floor, main rear riser, can be registered. Select floor number in Association
column.
• Hall call enable 1 (2) - Aux front input: When active, a valid call at the associated
secured floor, auxiliary front riser, can be registered. Select floor number in Associa-
tion column.
• Hall call enable 1 (2) - Aux rear input: When active, a valid call at the associated
secured floor, auxiliary rear riser, can be registered. Select floor number in Association
column.
• Hall call enable 1 (2) - Down aux front input: When active, a valid call at the associated
secured floor, down auxiliary front riser, can be registered. Select floor number in
Association column.
• Hall call enable 1 (2) - Down aux rear input: When active, a valid call at the associated
secured floor, down auxiliary rear riser, can be registered. Select floor number in Asso-
ciation column.
• Hall call enable 1 (2) - Up aux front input: When active, a valid call at the associated
secured floor, up auxiliary front riser, can be registered. Select floor number in Associ-
ation column.
• Hall call enable 1 (2) - Up aux rear input: When active, a valid call at the associated
secured floor, up auxiliary front riser, can be registered. Select floor number in Associ-
ation column.
• Hall call enable 1 (2) - Down main front input: When active, a valid call at the associ-
ated secured floor, down main front riser, can be registered. Select floor number in
Association column.
• Hall call enable 1 (2) - Down main rear input: When active, a valid call at the associated
secured floor, down main rear riser, can be registered. Select floor number in Associa-
tion column.
• Hall call enable 1 (2) - Up main front input: When active, a valid call at the associated
secured floor, up main front riser, can be registered. Select floor number in Association
column.