2 Parameters
2.2 List of parameters
SINAMICS DCP
100 List Manual (LH21), 05/2016
Description: Sets the signal source for external fault 1.
Dependency: Refer to: F07860
Note: An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
Description: Sets the signal source for external fault 2.
Dependency: Refer to: F07861
Note: An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
Description: Sets the signal source for external fault 2.
Dependency: Refer to: F07861
Note: An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
Description: Sets the signal source for external fault 3.
External fault 3 is initiated by the following AND logic operation:
- BI: p2108 negated
- BI: p3111
- BI: p3112 negated
Dependency: Refer to: p3110, p3111, p3112
Refer to: F07862
Note: An external fault is triggered with a 1/0 signal.
If this fault is output at the Control Unit, then it is transferred to all existing drive objects.
Description: Sets the signal source for external fault 3.
p2106[0...n] BI: External fault 1 / External fault 1
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 2546
Min Max Factory setting
- - 1
p2107 BI: External fault 2 / External fault 2
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: -
Min Max Factory setting
- - 1
p2107[0...n] BI: External fault 2 / External fault 2
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 2546
Min Max Factory setting
- - 1
p2108 BI: External fault 3 / External fault 3
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: -
Min Max Factory setting
- - 1
p2108[0...n] BI: External fault 3 / External fault 3
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 2546
Min Max Factory setting
- - 1