Siemens sinamics dcp - p4813 Function generator physical address reference value; FG phys addr ref; p4816 Function generator output signal integer number scaling; FG outp integ scal; r4817 CO: Function generator output signal integer number; FG outp integ no.; r4818 CO: Function generator output signal; FG outp_sig

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCP
List Manual (LH21), 05/2016
177
2 Parameters
2.2 List of parameters
Description: Sets the reference value for 100 % for referred inputs.
Dependency: Only effective when p4810 = 99.
Description: Sets the scaling for the integer number of the output signal for the function generator.
Dependency: Refer to: r4805, r4817
Note: The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
Description: Display and connector output for the integer number of the output signal for the function generator.
Dependency: Refer to: p4816
Note: The value is output independent of the function generator operating mode.
Description: Displays the output signal for the function generator.
Dependency: Refer to: p4810
Note: The value is displayed independently of the function generator mode.
Description: Sets the signal source to control the function generator.
When the function generator is running, signal generation is stopped with a 0 signal from BI: p4819 and p4800 is set
to 0.
Dependency: Refer to: p4800
Description: Sets the signal to be generated for the function generator.
p4813 Function generator physical address reference value / FG phys addr ref
CU_DCP Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
1.00 1000000.00 1.00
p4816 Function generator output signal integer number scaling / FG outp integ scal
CU_DCP Can be changed: U, T Access level: 4
Data type: Integer32 Func. diagram: -
Min Max Factory setting
-2147483648 2147483647 0
r4817 CO: Function generator output signal integer number / FG outp integ no.
CU_DCP Can be changed: - Access level: 4
Data type: Integer32 Func. diagram: -
Min Max Factory setting
- - -
r4818 CO: Function generator output signal / FG outp_sig
CU_DCP Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]
p4819 BI: Function generator control / FG control
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: -
Min Max Factory setting
- - 1
p4820 Function generator signal shape / FG signal shape
CU_DCP Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
1 5 1