SINAMICS DCP
List Manual (LH21), 05/2016
159
2 Parameters
2.2 List of parameters
Description: Setting to control the trace function.
Value: 0: Stop trace
1: Start trace
2: Start trace and save values
Index: [0] = Trace 0
[1] = Trace 1
Description: Setting to control the measurement function.
Value: 0: Stop measuring function
1: Start measuring function
2: Measuring function check parameterization
3: Start measuring function without enable signals
Description: Sets the options for the trace.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: p4700
Note: Re bit 00:
0: The trace starts with p4700 as before.
1: When powering up, the trace starts immediately with the saved parameter settings with the start of the time slices.
Description: Displays the actual status of the trace.
Value: 0: Trace inactive
1: Trace is recording presamples
2: Trace is waiting for trigger event
3: Trace is recording
4: Recording (trace) ended
Index: [0] = Trace 0
[1] = Trace 1
p4700[0...1] Trace control / Trace control
CU_DCP Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 2 0
p4701 Measuring function control / Meas fct ctrl
CU_DCP Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 3 0
p4703[0...1] Trace options / Trace options
CU_DCP Can be changed: T Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Automatically start trace with time slices Yes No -
r4705[0...1] Trace status / Trace status
CU_DCP Can be changed: - Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 4 -