SINAMICS DCP
List Manual (LH21), 05/2016
225
2 Parameters
2.2 List of parameters
Note: All indices from r9406 to r9408 designate the same parameter.
r9406[x] parameter number, parameter not accepted
r9407[x] parameter index, parameter not accepted
r9408[x] fault code, parameter not accepted
Description: Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency: Refer to: p0971, p0977
Notice: Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note: The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
Description: Displays the number of BICO interconnections (signal sinks).
Dependency: Refer to: r9482, r9483
Note: The selected BICO interconnections should be entered into r9482 and r9483.
Description: Displays the signal sinks (binector/connector inputs, BI/CI parameters).
The number of BICO interconnections is displayed in r9481.
Dependency: Refer to: r9481, r9483
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
Description: Displays the signal sources (binector/connector outputs, BO/CO parameters).
The number of BICO interconnections is displayed in r9481.
Dependency: Refer to: r9481, r9482
Note: The list is sorted according to signal sources and is structured as follows:
r9842[0]: Interconnection 1 (signal sink, BICO coded), r9843[0]: Interconnection 1 (signal source, BICO coded)
r9842[1]: Interconnection 2 (signal sink, BICO coded), r9843[1]: Interconnection 2 (signal source, BICO coded)
...
r9409 Number of parameters to be saved / Qty par to save
All objects Can be changed: - Access level: 4
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
- - -
r9481 Number of BICO interconnections / BICO count
All objects Can be changed: - Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
- - -
r9482[0...n] BICO interconnections BI/CI parameters / BICO BI/CI par
All objects Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -
r9483[0...n] BICO interconnections BO/CO parameters / BICO BO/CO par
All objects Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -