2 Parameters
2.2 List of parameters
SINAMICS DCP
182 List Manual (LH21), 05/2016
Dependency: Refer to: r4950, r4951, r4955, p4956, r4957, r4958, r4959, r4960
Note: The GUID of an OA application comprises 16 characters plus 1 character major information plus 1 character, minor
information.
GUID: Globally Unique IDentifier
Description: Displays the identifier of the OA applications installed on this drive object.
r4955[0...8]: Identifier of OA application 1
r4955[9...17]: Identifier of OA applications 2, ...
Dependency: Refer to: r4950, r4951, r4952, p4956, r4957, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Description: Setting to activate the OA applications installed on this drive object.
r4956[0]: Activates OA application 1
r4956[1]: Activates OA application 2, ...
Value: 0: OA application inactive
1: OA application active
Dependency: Refer to: r4950, r4951, r4952, r4955, r4957, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Description: Displays the version of the OA applications installed on this drive object.
r4957[0]: Version of OA application 1
r4957[1]: Version of OA application 2, ...
Dependency: Refer to: r4950, r4951, r4952, r4955, p4956, r4958, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the interface version of OA applications installed on this drive object.
r4958[0]: Interface version of OA application 1
r4958[1]: Interface version of OA applications 2, ...
Dependency: Refer to: r4950, r4951, r4952, r4955, p4956, r4957, r4959, r4960
Notice: If there is no OA application, then it is not possible to access an index.
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
r4955[0...n] OA DO-specific identifier / OA DO ident
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: - Access level: 4
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
- - -
p4956[0...n] OA DO-specific activation / OA DO act
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: C1, T Access level: 4
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 1 0
r4957[0...n] OA DO-specific version / OA DO version
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: - Access level: 4
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
0 4294967295 -
r4958[0...n] OA DO-specific interface version / OA DO interf_vers
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed: - Access level: 4
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -