2 Parameters
2.2 List of parameters
SINAMICS DCP
166 List Manual (LH21), 05/2016
Description: Selects the sixth signal to be traced.
Index: [0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
Description: Selects the seventh signal to be traced.
Index: [0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
Description: Selects the eighth signal to be traced.
Index: [0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
[2] = Trace 0 PINx with DO Id and chart Id
[3] = Trace 0 PINx with block Id and PIN Id
[4] = Trace 1 PINy with DO Id and chart Id
[5] = Trace 1 PINy with block Id and PIN Id
Description: Displays the trace buffer (record buffer) for trace 0 and signal 0.
The trace (record) buffer is sub-divided into memory banks, each containing 16384 values. Parameter p4795 can be
used to toggle between the individual banks.
Example A:
The first 16384 values of signal 0, trace 0 are to be read out.
In this case, memory bank 0 is set with p4795 = 0. The first 16384 values can now be read out using r4740[0] to
r4740[16383].
Example B:
The values 16385 to 32768 from signal 0, trace 0 are to be read out.
In this case, memory bank 1 is set with p4795 = 1. The values can now be read out in r4740[0] to r4740[16383].
Dependency: Refer to: p4795
p4735[0...5] Trace record signal 5 / Trace record sig 5
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - 0
p4736[0...5] Trace record signal 6 / Trace record sig 6
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - 0
p4737[0...5] Trace record signal 7 / Trace record sig 7
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - 0
r4740[0...16383] Trace 0 trace buffer signal 0 floating point / Trace 0 tr sig 0
CU_DCP Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- - -