2 Parameters
2.2 List of parameters
SINAMICS DCP
250 List Manual (LH21), 05/2016
Description: Sets the offset for the "main actual value" (XT1.103/104).
Notice: This analog input cannot be externally accessed. It is reserved for subsequent use.
Note: AI: Analog Input
Description: Sets the mode for signal processing for the "main actual value" analog input (XT1.103/104).
Value: 0: Signal not influenced
1: Signal absolute value generation
2: Signal inverted
3: Signal absolute value generation inverted
Notice: This analog input cannot be externally accessed. It is reserved for subsequent use.
Note: AI: Analog Input
Description: Sets the signal source for inverting the signal from the "main actual value" analog input (XT1.103/104).
0 signal: no inversion
1 signal: inversion
Notice: This analog input cannot be externally accessed. It is reserved for subsequent use.
Note: AI: Analog Input
Description: Sets the time constant for smoothing the signal from the "main actual value" analog input (XT1.103/104).
Notice: This analog input cannot be externally accessed. It is reserved for subsequent use.
Note: AI: Analog Input
Description: Sets the signal source for enabling the analog input for the "main actual value (XT1.103/104).
Notice: This analog input cannot be externally accessed. It is reserved for subsequent use.
Note: AI: Analog Input
p50742 Analog input main actual value offset / AI m act offs
DCP_CTRL Can be changed: U, T Access level: 4
Data type: FloatingPoint32 Func. diagram: 2075
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p50743 Analog input main actual value signal processing / AI m act sig
DCP_CTRL Can be changed: T Access level: 4
Data type: Integer16 Func. diagram: 2075
Min Max Factory setting
0 3 0
p50744 BI: Analog input main actual value inversion / AI m act inv
DCP_CTRL Can be changed: T Access level: 4
Data type: Unsigned32 / Binary Func. diagram: 2075
Min Max Factory setting
- - 0
p50745 Analog input main actual value smoothing time constant / AI m act T
DCP_CTRL Can be changed: U, T Access level: 4
Data type: FloatingPoint32 Func. diagram: 2075
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50746 BI: Signal source to enable analog input main actual value / AI m act ena s_src
DCP_CTRL Can be changed: T Access level: 4
Data type: Unsigned32 / Binary Func. diagram: 2075
Min Max Factory setting
- - 1