2 Parameters
2.2 List of parameters
SINAMICS DCP
114 List Manual (LH21), 05/2016
[4] = Fixed value +50 %
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
Dependency: Refer to: p2900, p2901, p2930
Note: The signal sources can, for example, be used to interconnect scalings.
Description: Setting and connector output for a fixed torque value.
Dependency: Refer to: p2900, p2901, r2902
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: The value can, for example, be used to interconnect a supplementary torque.
Description: Sets the mode for the time stamp
p3100 = 0: Time stamp, operating hours
p3100 = 1: Time stamp, UTC format
p3100 = 2: Time stamp, operating hours + 01.01.2000
Notice: The realtime format (p3100 = 1), once selected, remains until the next time that the system is switched off. Switching
back to operating hours (p3100 = 0) or operating hours + 01.01.2000 (p3100=2) is prevented.
Note: RTC: Real-time clock
UTC: Universal Time Coordinates
The UTC time started, according to the definition on 01.01.1970 at 00:00:00 and is output in days and milliseconds.
Description: Setting the UTC time.
This means that the drive system is synchronized to the time specified by the time master.
To start p3101[1] must be written to followed by p3101[0]. After writing to p3101[0], the UTC time is accepted.
p3101[0]: Milliseconds
p3101[1]: Days
p2930[0...n] CO: Fixed value M [Nm] / Fixed value M [Nm]
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
-100000.00 [Nm] 100000.00 [Nm] 0.00 [Nm]
p3100 RTC time stamp mode / RTC t_stamp mode
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
0 2 2
p3101[0...1] RTC set UTC time / RTC set UTC
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
0 4294967295 0