SINAMICS DCP
List Manual (LH21), 05/2016
217
2 Parameters
2.2 List of parameters
0512 hex: G120D
0513 hex: G120 CU250S-2 Vector
0514 hex: G110M
Description: Sets the station name for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8941, p8942, p8943, p8944, p8945
Note: An ASCII table (excerpt) can be found, for example, in the appendix to the List Manual.
The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the IP address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8942, p8943, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8943, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8944, p8945
Note: The interface configuration (p8940 and following) is activated with p8945.
The parameter is not influenced by setting the factory setting.
Description: Sets the DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Dependency: Refer to: p8940, p8941, p8942, p8943, p8945
p8940[0...239] CBE2x Name of Station / CBE2x Name Stat
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
- - -
p8941[0...3] CBE2x IP Address of Station / CBE2x IP of Stat
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
0 255 0
p8942[0...3] CBE2x Default Gateway of Station / CBE2x Def Gateway
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
0 255 0
p8943[0...3] CBE2x Subnet Mask of Station / CBE2x Subnet Mask
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
0 255 0
p8944 CBE2x DHCP Mode / CBE2x DHCP Mode
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned8 Func. diagram: -
Min Max Factory setting
0 255 0