2 Parameters
2.2 List of parameters
SINAMICS DCP
176 List Manual (LH21), 05/2016
Value: 0: Stop function generator
1: Start function generator
2: Check function generator parameterization
3: Start function generator without enable signals
Dependency: Refer to: p4819
Description: Displays the actual status of the function generator.
Value: 0: Inactive
1: Generate accelerating ramp to offset
2: Generate parameterized signal shape
3: Generate braking ramp
4: Function generator stopped due to missing enable signals
5: Function generator waits for BI: p4819
6: Function generator parameterization has been checked
Dependency: Refer to: p4800, p4819
Description: Displays the status of the function generator.
0 signal: Function generator inactive
1 signal: Function generator running
Description: Sets the operating mode of the function generator.
Value: 0: Connection at connector output r4818
1: Connection at current setpoint after filter and r4818
2: Connection as disturbing torque and r4818
3: Connection at speed setpoint after filter and r4818
4: Connection at current setpoint before filter and r4818
5: Connection at speed setpoint before filter and r4818
6: Connection for free measurement function r4818 and r4834
99: Connection at physical address and r4818
Description: Sets the physical address where the function generator is to be connected.
Dependency: Only effective when p4810 = 99.
r4805 Function generator status / FG status
CU_DCP Can be changed: - Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 6 -
r4806.0 BO: Function generator status signal / FG status signal
CU_DCP Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 ON OFF -
p4810 Function generator mode / FG operating mode
CU_DCP Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: -
Min Max Factory setting
0 99 0
p4812 Function generator physical address / FG phys address
CU_DCP Can be changed: U, T Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
0 4294967295 0