Siemens sinamics dcp - p50785 CUD digital input;output 4 output delay time; DI;DO 4 t_del_out; p50786 CUD digital input;output 5 output delay time; DI;DO 5 t_del_out; p50787 CUD digital input;output 6 output delay time; DI;DO 6 t_del_out; p50788 CUD digital input;output 7 output delay time; DI;DO 7 t_del_out

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCP
256 List Manual (LH21), 05/2016
Dependency: The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
Note: DI/DO: bidirectional digital input/digital output
Description: Sets the delay time for digital input/output 4 (DI/DO 4, X177.15) on the CUD.
Dependency: The terminal must be set as an output (p50789[0] = 1).
Refer to: p50789
Note: DI/DO: bidirectional digital input/digital output
Description: Sets the delay time for digital input/output 5 (DI/DO 5, X177.16) on the CUD.
Dependency: The terminal must be set as an output (p50789[1] = 1).
Refer to: p50789
Note: DI/DO: bidirectional digital input/digital output
Description: Sets the delay time for digital input/output 6 (DI/DO 6, X177.17) on the CUD.
Dependency: The terminal must be set as an output (p50789[2] = 1).
Refer to: p50789
Note: DI/DO: bidirectional digital input/digital output
Description: Sets the delay time for digital input/output 7 (DI/DO 7, X177.18) on the CUD.
Dependency: The terminal must be set as an output (p50789[3] = 1).
Refer to: p50789
Note: DI/DO: bidirectional digital input/digital output
Description: Sets the type for digital input/output 4 ... 7 (DI/DO 4 ... DI/DO 7) of the CUD.
Value: 0: Input
1: Output
p50785 CUD digital input/output 4 output delay time / DI/DO 4 t_del_out
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2060
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50786 CUD digital input/output 5 output delay time / DI/DO 5 t_del_out
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2060
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50787 CUD digital input/output 6 output delay time / DI/DO 6 t_del_out
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2065
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50788 CUD digital input/output 7 output delay time / DI/DO 7 t_del_out
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2065
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]
p50789[0...3] CUD digital input/output 4 ... 7 type / CUD DI/DO typ
DCP_CTRL Can be changed: T Access level: 3
Data type: Integer16 Func. diagram: 2060, 2065
Min Max Factory setting
0 1 0