SINAMICS DCP
List Manual (LH21), 05/2016
269
2 Parameters
2.2 List of parameters
Dependency: For bit 08 ... 15:
The terminal must be set as an input (p50789[0...3] = 0).
Note: DI: Digital Input
DI/DO: bidirectional digital input/digital output
Description: Display and connector output for the CUD's digital outputs.
Dependency: For bits 04 ... 07:
The terminal must be set as an output (p50789[0...3] = 1).
Note: DO: Digital Output
DI/DO: bidirectional digital input/digital output
Description: Display and connector output for the overload monitoring of the digital outputs.
Dependency: For bits 04 ... 07:
The terminal must be set as an output (p50789[0...3] = 1).
Note: DO: Digital Output
DI/DO: bidirectional digital input/digital output
06 DI 3 (X177.14) High Low 2050
07 DI 3 inverted (X177.14) High Low 2050
08 DI/DO 4 (X177.15) High Low 2060
09 DI/DO 4 inverted (X177.15) High Low 2060
10 DI/DO 5 (X177.16) High Low 2060
11 DI/DO 5 inverted (X177.16) High Low 2060
12 DI/DO 6 (X177.17) High Low 2065
13 DI/DO 6 inverted (X177.17) High Low 2065
14 DI/DO 7 (X177.18) High Low 2065
15 DI/DO 7 inverted (X177.18) High Low 2065
r53020.0...7 CO/BO: CUD digital outputs status / CUD DO status
DCP_CTRL Can be changed: - Access level: 3
Data type: Unsigned16 Func. diagram: 2055, 2060,
2065
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (X177.19) High Low 2055
01 DO 1 (X177.20) High Low 2055
02 DO 2 (X177.21) High Low 2055
03 DO 3 (X177.22) High Low 2055
04 DI/DO 4 (X177.15) High Low 2060
05 DI/DO 5 (X177.16) High Low 2060
06 DI/DO 6 (X177.17) High Low 2065
07 DI/DO 7 (X177.18) High Low 2065
r53021.0...7 CO/BO: CUD digital outputs overload monitoring / CUD DO overl_monit
DCP_CTRL Can be changed: - Access level: 3
Data type: Unsigned16 Func. diagram: 2055, 2060,
2065
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DO 0 (X177.19) overload present Yes No 2055
01 DO 1 (X177.20) overload present Yes No 2055
02 DO 2 (X177.21) overload present Yes No 2055
03 DO 3 (X177.22) overload present Yes No 2055
04 DI/DO 4 (X177.15) overload present Yes No 2060
05 DI/DO 5 (X177.16) overload present Yes No 2060
06 DI/DO 6 (X177.17) overload present Yes No 2065
07 DI/DO 7 (X177.18) overload present Yes No 2065