2 Parameters
2.2 List of parameters
SINAMICS DCP
268 List Manual (LH21), 05/2016
Description: Display and connector output for the external temperature (terminal X177.53-55).
Description: Display and connector output for fixed value 1 set in p50401.
Dependency: Refer to: p50401
Description: Display and connector output for fixed value 2 set in p50402.
Dependency: Refer to: p50402
Description: Display and connector output for fixed value 3 set in p50403.
Dependency: Refer to: p50403
Description: Display and connector output for the sequence control operating state.
Note: The value corresponds to operating display r0002 (DCP_CTRL).
Description: Display and connector output for the CUD's digital inputs.
r52052 CO: Temperature sensor external display / Temp_sens ext disp
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 8030
Min Max Factory setting
- [°C] - [°C] - [°C]
r52401 CO: Fixed value 1 display / Fix val 1 disp
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52402 CO: Fixed value 2 display / Fix val 2 disp
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52403 CO: Fixed value 3 display / Fix val 3 disp
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52800 CO: Sequence control operating state / Seq_ctr op_state
DCP_CTRL Can be changed: - Access level: 2
Data type: Unsigned16 Func. diagram: 2650
Min Max Factory setting
- - -
r53010.0...15 CO/BO: CUD digital inputs status / CUD DI status
DCP_CTRL Can be changed: - Access level: 3
Data type: Unsigned16 Func. diagram: 2050, 2060,
2065
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X177.11) High Low 2050
01 DI 0 inverted (X177.11) High Low 2050
02 DI 1 (X177.12) High Low 2050
03 DI 1 inverted (X177.12) High Low 2050
04 DI 2 (X177.13) High Low 2050
05 DI 2 inverted (X177.13) High Low 2050