2 Parameters
2.2 List of parameters
SINAMICS DCP
300 List Manual (LH21), 05/2016
Description: Displays the speeds for the device fan.
r55480[0]: device fan 1
r55480[1]: device fan 2
r55480[2]: device fan 3
Note: This parameter only shows the actual fan speed for device types equipped with variable-speed fans.
30 kW device:
- the fans are not variable-speed fans.
- a value of zero is indicated in r55480[0...2].
120 kW device:
- the fans are variable-speed fans.
- the actual speeds are displayed in r55480[0...2].
Description: Display and connector output for the voltage on side 1.
Description: Display and connector output for the voltage on side 2.
Description: Display for the voltage on side 1.
Description: Display for the voltage on side 2.
Description: Display and connector output for the inner voltage on side 1.
r55480[0...2] Device fan speed / Device fan n
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6845
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r55501 CO: Actual value voltage side 1 / Act val U S1
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6818, 6850
Min Max Factory setting
- [%] - [%] - [%]
r55502 CO: Actual value voltage side 2 / Act val U S2
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6818, 6850
Min Max Factory setting
- [%] - [%] - [%]
r55503 Actual value voltage side 1 / Act val U S1
DCP_CTRL Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [V] - [V] - [V]
r55504 Actual value voltage side 2 / Act val U S2
DCP_CTRL Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 6850
Min Max Factory setting
- [V] - [V] - [V]
r55505 CO: Actual value voltage inner side 1 / Act val U inner S1
DCP_CTRL Can be changed: - Access level: 2
Data type: FloatingPoint32 Func. diagram: 6818, 6850
Min Max Factory setting
- [%] - [%] - [%]