SINAMICS DCP
List Manual (LH21), 05/2016
107
2 Parameters
2.2 List of parameters
Dependency: Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2127
Note: Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
Description: Selects the faults for which the acknowledge mode is to be changed
Dependency: Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2127
Note: Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
Description: Sets the acknowledge mode for selected fault.
Value: 1: Acknowledgment only using POWER ON
2: Ack IMMEDIATELY after the fault cause has been removed
3: Acknowledgement only for PULSE INHIBIT
Dependency: Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice: It is not possible to re-parameterize the acknowledge mode for a fault in the following cases:
- Fault number does not exist (exception value = 0).
- Message type is not "fault" (F).
- Acknowledge mode is not permissible for the set fault number.
Note: Re-parameterization is also possible if a fault is present. The change only becomes effective after the fault has been
resolved.
The acknowledge mode can only be changed for faults with the appropriate identification.
Example:
F12345 and acknowledge mode = IMMEDIATELY (POWER ON)
--> The acknowledge mode can be changed from IMMEDIATELY to POWER ON.
Description: Sets the acknowledge mode for selected fault.
Value: 1: Acknowledgment only using POWER ON
2: Ack IMMEDIATELY after the fault cause has been removed
3: Acknowledgement only for PULSE INHIBIT
Dependency: Selects the faults and sets the required acknowledge mode realized under the same index
Refer to: p2126
Notice: It is not possible to re-parameterize the acknowledge mode for a fault in the following cases:
- Fault number does not exist (exception value = 0).
- Message type is not "fault" (F).
- Acknowledge mode is not permissible for the set fault number.
p2126[0...19] Change acknowledge mode fault number / Chng ackn F_no
TM150, TM15DI_DO,
TM31
Can be changed: U, T Access level: 3
Data type: Unsigned16 Func. diagram: 8050, 8075
Min Max Factory setting
0 65535 0
p2127[0...19] Change acknowledge mode mode / Chng ackn mode
CU_DCP, DCP_CTRL Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: 8075
Min Max Factory setting
1 3 1
p2127[0...19] Change acknowledge mode mode / Chng ackn mode
TM150, TM15DI_DO,
TM31
Can be changed: U, T Access level: 3
Data type: Integer16 Func. diagram: 8050, 8075
Min Max Factory setting
1 3 1