2 Parameters
2.2 List of parameters
SINAMICS DCP
142 List Manual (LH21), 05/2016
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency: The unit of this parameter (V or mA) depends on the analog output type.
Refer to: p4076
Notice: This parameter is automatically overwritten when changing p4076 (type of analog outputs).
Note: The parameters for the characteristic do not have a limiting effect.
Description: Sets the signal source to invert the analog output signals of Terminal Module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Description: Sets the offset for the analog outputs of Terminal Module 31 (TM31).
The offset is added to the output signal after the scaling characteristic.
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Dependency: The unit of this parameter (V or mA) depends on the analog input type.
Refer to: p4076
Note: This means, for example, the offset of a downstream isolating amplifier can be compensated.
Description: Sets the signal source for terminal DI/DO 16 (X522.2) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.16 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 17 (X522.3) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.17 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 18 (X522.4) of Terminal Module 15 (TM15).
p4082[0...1] BI: TM31 analog outputs invert signal source / TM31 AO inv s_src
TM31 Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 9572
Min Max Factory setting
- - 0
p4083[0...1] TM31 analog outputs offset / TM31 AO offset
TM31 Can be changed: U, T Access level: 1
Data type: FloatingPoint32 Func. diagram: 9572
Min Max Factory setting
-20.000 20.000 0.000
p4086 BI: TM15DI/DO signal source for terminal DI/DO 16 / TM15D s_srcDI/DO16
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9402
Min Max Factory setting
- - 0
p4087 BI: TM15DI/DO signal source for terminal DI/DO 17 / TM15D s_srcDI/DO17
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9402
Min Max Factory setting
- - 0
p4088 BI: TM15DI/DO signal source for terminal DI/DO 18 / TM15D s_srcDI/DO18
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9402
Min Max Factory setting