2 Parameters
2.2 List of parameters
SINAMICS DCP
264 List Manual (LH21), 05/2016
Description: Connector output with constant fixed value value 50 %.
Description: Connector output with constant fixed value value 150 %.
Description: Connector output with constant fixed value value -50 %.
Description: Connector output with constant fixed value -150%.
Description: Display and connector output for the raw value at the "Main setpoint" analog input (X177.25/26).
Note: AI: Analog Input
Description: Display and connector output for the "Main setpoint" analog input (X177.25/26).
Note: AI: Analog Input
Description: Display and connector output for the raw value at the "Main actual value" analog input (XT1.103/104).
Note: AI: Analog Input
r52005 CO: Fixed value 50 % / Fix val 50 %
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52006 CO: Fixed value 150 % / Fix val 150 %
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52007 CO: Fixed value -50 % / Fix val -50 %
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52008 CO: Fixed value -150 % / Fix val -150 %
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 3100
Min Max Factory setting
- [%] - [%] - [%]
r52010 CO: CUD analog input main setpoint raw value / CUD AI m set raw
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 2075
Min Max Factory setting
- [%] - [%] - [%]
r52011 CO: CUD analog input main setpoint / CUD AI m set
DCP_CTRL Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: 2075
Min Max Factory setting
- [%] - [%] - [%]
r52012 CO: CUD analog input main actual value raw value / CUD AI m act raw
DCP_CTRL Can be changed: - Access level: 4
Data type: FloatingPoint32 Func. diagram: 2075
Min Max Factory setting
- [%] - [%] - [%]