EasyManuals Logo

Siemens sinamics dcp User Manual

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
2 Parameters
2.2 List of parameters
SINAMICS DCP
216 List Manual (LH21), 05/2016
Description: Setting to invert the individual binector outputs of the connector-binector converter.
Using p8898[0], the signals of CI: p8899[0] are influenced.
Using p8898[1], the signals of CI: p8899[1] are influenced.
Dependency: Refer to: r8894, r8895, p8899
Description: Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency: Refer to: r8850, r8894, r8895, p8898
Note: From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p8899[0...1] together with r8894.0...15 and r8895.0...15 forms two connector-binector converters:
Connector input p8899[0] to binector output in r8894.0...15
Connector input p8899[1] to binector output in r8895.0...15
Description: Displays the PROFINET Device ID.
Every SINAMICS device type has its own PROFINET Device ID and its own PROFINET GSD.
Note: List of the SINAMICS Device IDs:
0501 hex: S120/S150
0504 hex: G130/G150
050A hex: DC MASTER
050C hex: MV
050F hex: G120P
0510 hex: G120C
0511 hex: G120 CU240E-2
p8898[0...1] IF2 invert connector-binector converter binector output / Con/bin outp inv
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned16 Func. diagram: 2485, 2491
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Bit 0 Inverted Not inverted -
01 Bit 1 Inverted Not inverted -
02 Bit 2 Inverted Not inverted -
03 Bit 3 Inverted Not inverted -
04 Bit 4 Inverted Not inverted -
05 Bit 5 Inverted Not inverted -
06 Bit 6 Inverted Not inverted -
07 Bit 7 Inverted Not inverted -
08 Bit 8 Inverted Not inverted -
09 Bit 9 Inverted Not inverted -
10 Bit 10 Inverted Not inverted -
11 Bit 11 Inverted Not inverted -
12 Bit 12 Inverted Not inverted -
13 Bit 13 Inverted Not inverted -
14 Bit 14 Inverted Not inverted -
15 Bit 15 Inverted Not inverted -
p8899[0...1] CI: IF2 connector-binector converter signal source / Con/bin S_src
DCP_CTRL Can be changed: U, T Access level: 3
Data type: Unsigned32 / Integer16 Func. diagram: 2485, 2491
Min Max Factory setting
- - 0
r8909 PN device ID / PN device ID
CU_DCP Can be changed: - Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
- - -

Table of Contents

Other manuals for Siemens sinamics dcp

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens sinamics dcp and is the answer not in the manual?

Siemens sinamics dcp Specifications

General IconGeneral
BrandSiemens
Modelsinamics dcp
CategoryMedia Converter
LanguageEnglish

Related product manuals