2 Parameters
2.2 List of parameters
SINAMICS DCP
194 List Manual (LH21), 05/2016
Description: Sets the send configuration data for the COMM BOARD.
The setting is activated with p8842.
Dependency: Refer to: p8842
Note: The configuration data are specific to the inserted COMM BOARD.
For CBE20, the configuration data are not relevant.
Description: Activate a modified send configuration for COMM BOARD.
With p8842 = 1, the values in p8841 are transferred to the COMM BOARD and activated. After this, p8842 is
automatically set to zero.
Dependency: Refer to: p8841
Note: For CBE20, certain SINAMICS parameters are newly evaluated and activated. An existing, cyclic bus connection is
interrupted.
Description: Displays the PROFIdrive PZD state.
Dependency: Refer to: p2044
Note: When using the "setpoint failure" signal, the bus can be monitored and an application-specific response triggered
when the setpoint fails.
Description: Sets the delay time to initiate fault F01910 after a setpoint failure.
The time until the fault is initiated can be used by the application. This means that is is possible to respond to the
failure while the drive is still operational (e.g. emergency retraction).
Dependency: Refer to: r2043
Refer to: F01910
Description: Sets the sampling time for the cyclic interface 2 (IF2).
p8841[0...239] COMM BOARD send configuration data / CB s config_dat
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
0 65535 0
p8842 Activate COMM BOARD send configuration / CB s config act
CU_DCP (PROFINET
CBE20)
Can be changed: U, T Access level: 3
Data type: Unsigned16 Func. diagram: -
Min Max Factory setting
0 1 0
r8843.0...2 BO: IF2 PZD state / IF2 PZD state
CU_DCP Can be changed: - Access level: 3
Data type: Unsigned8 Func. diagram: 2410
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Setpoint failure Yes No -
02 Fieldbus oper Yes No -
p8844 IF2 fault delay / IF2 F delay
DCP_CTRL Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 2410
Min Max Factory setting
0 [s] 100 [s] 0 [s]
p8848 IF2 PZD sampling time / IF2 PZD t_sample
CU_DCP Can be changed: C1(3) Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
1.00 [ms] 16.00 [ms] 4.00 [ms]