Siemens sinamics dcp - p4035 BI: TM15 DI;DO signal source for terminal DI;DO 5; TM15 D S_src DI;DO5; p4036 BI: TM15 DI;DO signal source for terminal DI;DO 6; TM15 D S_src DI;DO6; p4037 BI: TM15 DI;DO signal source for terminal DI;DO 7; TM15 D s_src DI;DO7; p4038 BI: TM15 DI;DO signal source for terminal DI;DO 8; TM15 D s_src DI;DO8

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCP
List Manual (LH21), 05/2016
131
2 Parameters
2.2 List of parameters
Description: Sets the signal source for terminal DI/DO 5 (X520.7) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.5 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 6 (X520.8) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.6 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 7 (X520.9) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.7 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 8 (X521.2) of Terminal Module 15 (TM15).
Note: Prerequisite: The DI/DO must be set as an output (p4028.8 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 8 (X541.2) of Terminal Module 31 (TM31).
Note: Prerequisite: The DI/DO must be set as an output (p4028.8 = 1).
DI/DO: Bidirectional Digital Input/Output
Description: Sets the signal source for terminal DI/DO 9 (X521.3) of Terminal Module 15 (TM15).
p4035 BI: TM15DI/DO signal source for terminal DI/DO 5 / TM15D S_src DI/DO5
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9400
Min Max Factory setting
- - 0
p4036 BI: TM15DI/DO signal source for terminal DI/DO 6 / TM15D S_src DI/DO6
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9400
Min Max Factory setting
- - 0
p4037 BI: TM15DI/DO signal source for terminal DI/DO 7 / TM15D s_src DI/DO7
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9400
Min Max Factory setting
- - 0
p4038 BI: TM15DI/DO signal source for terminal DI/DO 8 / TM15D s_src DI/DO8
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9401
Min Max Factory setting
- - 0
p4038 BI: TM31 signal source for terminal DI/DO 8 / TM31 S_src DI/DO8
TM31 Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9549, 9560
Min Max Factory setting
- - 0
p4039 BI: TM15DI/DO signal source for terminal DI/DO 9 / TM15D s_src DI/DO9
TM15DI_DO Can be changed: U, T Access level: 1
Data type: Unsigned32 / Binary Func. diagram: 9401
Min Max Factory setting
- - 0