Siemens sinamics dcp - p4067[0...1] BI: TM31 analog inputs invert signal source; TM31 AI inv s_src; p4068[0...1] TM31 analog inputs window to suppress noise; TM31 AI window; p4069[0...1] BI: TM31 analog inputs signal source for enable; TM31 AI enable; p4071[0...1] CI: TM31 analog outputs signal source; TM31 AO s_src

Siemens sinamics dcp
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCP
List Manual (LH21), 05/2016
139
2 Parameters
2.2 List of parameters
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description: Sets the signal source to invert the analog inputs signals of Terminal Module 31 (TM31).
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description: Sets the noise suppression window of the analog inputs for Terminal Module 31 (TM31).
Changes less than the window are suppressed.
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Note: AI: Analog Input
Description: Sets the signal source for the enable signal of the analog inputs of Terminal Module 31 (TM31).
Index: [0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Description: Sets the signal source for the analog outputs of Terminal Module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
Note: AO: Analog Output
Description: Displays the actual referred output value of the analog outputs of Terminal Module 31 (TM31).
Index: [0] = AO 0 (X522.1, X522.2, X522.3)
[1] = AO 1 (X522.4, X522.5, X522.6)
p4067[0...1] BI: TM31 analog inputs invert signal source / TM31 AI inv s_src
TM31 Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 9566, 9568
Min Max Factory setting
- - 0
p4068[0...1] TM31 analog inputs window to suppress noise / TM31 AI window
TM31 Can be changed: U, T Access level: 3
Data type: FloatingPoint32 Func. diagram: 9566, 9568
Min Max Factory setting
0.00 [%] 20.00 [%] 0.00 [%]
p4069[0...1] BI: TM31 analog inputs signal source for enable / TM31 AI enable
TM31 Can be changed: U, T Access level: 3
Data type: Unsigned32 / Binary Func. diagram: 9566, 9568
Min Max Factory setting
- - 1
p4071[0...1] CI: TM31 analog outputs signal source / TM31 AO s_src
TM31 Can be changed: U, T Access level: 1
Data type: Unsigned32 / FloatingPoint32 Func. diagram: 9549, 9572
Min Max Factory setting
- - 0
r4072[0...1] TM31 analog outputs output value currently referred / TM31 AO outp_val
TM31 Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 9572
Min Max Factory setting
- [%] - [%] - [%]