2 Parameters
2.2 List of parameters
SINAMICS DCP
238 List Manual (LH21), 05/2016
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Description: Displays the memory usage of an OA application.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Description: Diagnostics parameter to display additional information for internal software errors.
Note: Only for internal Siemens troubleshooting.
Description: o0.0 No current direction switched on
o0.1 Current direction I switched on
o0.2 Current direction II switched on
o1.2 Wait for operating enable (signal source acc. to p0852)
o4.2 Wait until precharging has been completed
o7.1 Wait for switch-on (signal source according to p0840)
o7.5 Wait until offset calibration has been completed
o8.0 Wait for switching-on inhibited to be acknowledged
o8.1 Simulation mode active (see p55270)
o8.2 Wait until the power unit has cooled down (5 min)
o8.3 Contactor test active (p55370)
o9.1 Quick stop (OFF3) (signal source acc. to p0848) present
o9.2 Quick stop (OFF3) (signal source acc. to p0849) present
o10.1 Voltage disconnect (OFF2) (signal source acc. to p0844) pending
o10.2 Voltage disconnect (OFF2) (signal source acc. to p0845) pending
o11.0 Fault
o12.3 Read-out calibration data
o12.4 Offset calibr. of curr. act. val. sensing being performed
o12.5 Read out data from the power unit
o12.6 Wait until the second processors go into normal operation
r9993[0...4] Memory usage OA application / Mem_use OA
CU_DCP Can be changed: - Access level: 4
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -
r9999[0...99] Software error internal supplementary diagnostics / SW_err int diag
CU_DCP Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: -
Min Max Factory setting
- - -
r50000 Operating display / Op_display
DCP_CTRL Can be changed: - Access level: 1
Data type: FloatingPoint32 Func. diagram: 2650, 6855
Min Max Factory setting
- - -