SINAMICS DCP
List Manual (LH21), 05/2016
105
2 Parameters
2.2 List of parameters
Description: Displays the number of alarms that have occurred.
Dependency: Refer to: r2110, r2123, r2124, r2125, r2134, r2145, r2146, r3121, r3123
Notice: The properties of the alarm buffer should be taken from the corresponding product documentation.
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Alarm buffer structure (general principle):
r2122[0], r2124[0], r2123[0], r2125[0] --> alarm 1 (the oldest)
. . .
r2122[7], r2124[7], r2123[7], r2125[7] --> Alarm 8 (the latest)
When the alarm buffer is full, the alarms that have gone are entered into the alarm history:
r2122[8], r2124[8], r2123[8], r2125[8] --> Alarm 1 (the latest)
. . .
r2122[63], r2124[63], r2123[63], r2125[63] --> alarm 56 (the oldest)
Description: Displays the number of alarms that have occurred.
Dependency: Refer to: r2110, r2123, r2124, r2125, r2134, r2145, r2146, r3121, r3123
Notice: The properties of the alarm buffer should be taken from the corresponding product documentation.
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Alarm buffer structure (general principle):
r2122[0], r2124[0], r2123[0], r2125[0] --> alarm 1 (the oldest)
. . .
r2122[7], r2124[7], r2123[7], r2125[7] --> Alarm 8 (the latest)
When the alarm buffer is full, the alarms that have gone are entered into the alarm history:
r2122[8], r2124[8], r2123[8], r2125[8] --> Alarm 1 (the latest)
. . .
r2122[63], r2124[63], r2123[63], r2125[63] --> alarm 56 (the oldest)
Description: Displays the system runtime in milliseconds when the alarm occurred.
Dependency: Refer to: r2110, r2114, r2122, r2124, r2125, r2134, r2145, r2146, r3121, r3123
Notice: The time comprises r2145 (days) and r2123 (milliseconds).
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
The structure of the alarm buffer and the assignment of the indices is shown in r2122.
Description: Displays the system runtime in milliseconds when the alarm occurred.
r2122[0...63] Alarm code / Alarm code
CU_DCP, DCP_CTRL Can be changed: - Access level: 2
Data type: Unsigned16 Func. diagram: 8065
Min Max Factory setting
- - -
r2122[0...63] Alarm code / Alarm code
TM150, TM15DI_DO,
TM31
Can be changed: - Access level: 2
Data type: Unsigned16 Func. diagram: 8050, 8065
Min Max Factory setting
- - -
r2123[0...63] Alarm time received in milliseconds / t_alarm recv ms
CU_DCP, DCP_CTRL Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: 8065
Min Max Factory setting
- [ms] - [ms] - [ms]
r2123[0...63] Alarm time received in milliseconds / t_alarm recv ms
TM150, TM15DI_DO,
TM31
Can be changed: - Access level: 3
Data type: Unsigned32 Func. diagram: 8050, 8065
Min Max Factory setting
- [ms] - [ms] - [ms]