2 Parameters
2.2 List of parameters
SINAMICS DCP
236 List Manual (LH21), 05/2016
Note: The corresponding sampling times can be read out in parameter r7901.
Net utilization:
Computing time load that is only called by the sampling time involved.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
Description: Displays the calculated data memory utilization rates based on the existing target topology.
Index: [0] = Fast data memory 1
[1] = Fast data memory 2
[2] = Fast data memory 3
[3] = Fast data memory 4
[4] = Reserved
Dependency: Refer to: F01068
Description: Displays the measured data memory utilization rates based on the existing target topology.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Dependency: Refer to: F01068
Description: Displays the utilization of the data memory by OA applications.
Index: [0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Reserved
Dependency: Refer to: F01068
Description: Displays the calculated DRIVE-CLiQ system load based on the existing target topology.
The values are not made available until the RUNUP READY (800) state is adopted (see p3988).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency: Refer to: F01340
r9982[0...4] Data memory utilization / Mem_util dat_mem
CU_DCP Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]
r9983[0...4] Measured data memory utilization (actual load) / Mem_ut dat_mem ms
CU_DCP Can be changed: - Access level: 4
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]
r9984[0...4] Data memory utilization OA / Mem_ut dat_mem OA
CU_DCP Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]
r9986[0...7] DRIVE-CLiQ system load / DQ system load
CU_DCP Can be changed: - Access level: 3
Data type: FloatingPoint32 Func. diagram: -
Min Max Factory setting
- [%] - [%] - [%]